Main Service Pipe

Ductile cast iron pipe is a pipe type preferred in main transmission lines since it has superior properties such as corrosion strength and abrasion resistance as it is made of cast iron, as well as being able to stretch without deformation. In regions where the temperature is low, freezing frequently occurs on the main transmission lines, especially in winter. Such problems can be avoided by using pre-insulated geothermal ductile iron pipes.

Technical Specifications

General Design

ISO 2351

TS EN 545

EN 598

Pipe Socket and Gasket

DIN 28603

EN681-1

Flange Sizes

EN 1092-2

ISO 7005-2

BS 4504

DIN 2501

Internal Coating

ISO 4179

External Coating

ISO 8179

Polyethylene Coating(Optional)

ISO 8180

Rigid Polyurethane (PUR) Insulation

Rigid polyurethane foam is an insulation material with an extremely low thermal transmission coefficient, consisting of the mixing of polyol and isocyanate in certain ratios and pressure injection of these materials. PUR, which is injected between the carrier pipe and the casing pipe (HDPE), provides heat insulation as well as enables two pipes to operate as one pipe by bonding them together and filling in the space between the pipes longitudinally. In the manufacturing of pre-insulated geothermal pipes, the PUR in accordance with the standard TS EN 253 has to meet the following minimum requirements:

Technical Specifications

Components

Polyol and Isocyanate

Minimum cellular mass density

55 kg/m3 ISO 845

Max. Thermal Conductivity Coefficient

0,029 W/mK ISO 8497

Average cell structure

< 0,5 mm

Closed cell content

> %88 ISO 4590

Min. Radial Compressive Strength

0,30 MPa ISO 844

Water absorption at high temperature

< 10% when tested according to TS EN 253 5.3.5

Axial cutting strength

23 °C ± 2 °C ≥ 0,12 N/mm²

140 °C ± 2 °C ≥ 0,08 N/mm²

Temperature range

-50 °C / +148 °C

Impact strength

No damage must exist - when tested in accordance with EN 253 5.4.5
ISO 3127

Linear Water Tightness

Must be Watertight When tested in accordance with EN 253 5.4.6

Chlorofluorocarbon

None

Service life of insulation according to continuous service temperature

3 years at 140 ˚C

30 years at 120 ˚C

50 years at 115 ˚C

HDPE Casing Pipe

Extruded polyethylene casing pipe is used on the outermost part, which protects the insulation material from external factors and chemicals. The HDPE casing pipe manufactured in accordance with the standards TS EN 253 and TS EN 12201-2 must contain antioxidants, UV stabilizers and carbon black.

Standard

EN 253, EN 12201-2

Dimensions

EN 253 part4.3.2.2 table 5

Material

PE 80 – PE 100 ISO 9080

Density

> 944 kg/m3 ISO 1133

Thermal Conductivity Coefficient

0,43 W/mK

Thermal Stability (OIT)

> 20 min (210 °C) ISO 11357-6

Temperature Range

40 °C / + 80 °C

Cracking resistance under stress

> 300 hrs (4 MPa, 80 °C) ISO 16770

Post-thermal treatment changes

<%3 (no damage must exist) ISO 2505

Melt Flow Index (MFI 190°C/5kg)

0,2 < MFR ≤ 1,0 g/10dk ISO 1133

Carbon black content

> by mass % 2,5 ± 0,5 ISO 6964

Carbon black propagation degree

<3 ISO 18553

Breaking elongation

>% 350 ISO 6259-1

Hydrostatic Strength

10,8 bar

80°C 165 sa ISO 1167-1-2

Inner surface treatment

Corona process on extruded line (on-line)

UV Protection

yes

Ductile Iron Pipes
PRODUCT NOMINAL SIZE DUCTILE PIPE HDPE CASING PIPE PUR PIPE LENGTH INSULATED PIPE WEIGHT (kg/m)
DN INCH Outer Diameter dₐ (mm) Wall Thickness t (mm)**** kg/m Outer Diameter D (mm) Wall Thickness s (mm) Inner Diameter (mm) Thickness (mm) L (mt)
Ø 80/200 80 3" 98 6,00 12,20 200 3,2 193,6 47,8 6 15,78
Ø 100/250 100 4" 118 6,10 15,10 250 3,6 242,8 62,4 6 20,52
Ø 125/280 125 5" 144 6,20 18,90 280 3,9 272,2 64,1 6-12 25,41
Ø 150/315 150 6" 170 6,30 22,80 315 4,1 306,8 68,4 6-12 30,63
Ø 200/355 200 8" 222 6,30 33,51 355 4,5 346,0 62 6-12 42,59
Ø 250/400 250 10" 274 6,80 40,20 400 4,8 390,4 58,2 6-12 50,69
Ø 300/450 300 12" 326 7,20 50,80 450 5,2 439,6 56,8 6-12 63,14
Ø 350/500 350 14" 378 7,70 63,20 500 5,6 488,8 55,4 6-12 77,53
Ø 400/560 400 16" 429 8,10 75,50 560 6,0 548,0 59,5 6-12 93,03
Ø 450/630 450 18" 480 8,60 89,90 630 6,6 616,8 68,4 6-12 111,89
Ø 500/710 500 20" 508 9,00 110,75 710 7,2 695,6 93,8 6-12 140,24
Ø 600/800 600 24" 610 9,90 146,50 800 7,9 784,2 87,1 6-12 180,76
Ø 700/900 700 28" 711 10,80 186,48 900 8,7 882,6 85,8 6-12 227,20
Ø 800/1000 800 32" 812,8 11,70 231,13 1000 9,4 981,2 84,2 6-12 278,21
Ø 900/1100 900 36" 914 12,60 280,08 1100 10,2 1079,6 82,8 6-12 334,63
Ø 1000/1200 1000 40" 1016 13,50 333,74 1200 11,0 1178,0 81 6-12 395,66
Ø 1200/1400 1200 48" 1219 14,40 427,76 1400 12,5 1375,0 78 6-12 505,76
  • Non-insulated pipe ends will have a length of 150 - 250 mm ±10 mm.
  • Upon request, manufacturing can be made in lengths, diameters and insulation thicknesses different from the values in the table.
  • Our company reserves the right to make changes on this and all other data in the brochures, written documentation and on our website. You may contact our company for getting up-to-date information.
  • The outer diameter, wall thickness and unit weight of the ductile pipe are based on the K9 production standard. The values may vary in different production standards.
 
;